資訊中心
News Center9月13日
951
瀏覽【照明電器行業(yè)動態(tài)信息】夾子燈技術要求變更
隨著IEC60598-1:2014+A1:2017在2017年9月15日發(fā)布并實施,針對移動式夾子燈的鉗夾裝置的評估測試要求發(fā)生變更,產品將相對更容易通過測試。
以下是新舊測試要求對比:
舊要求(IEC60598-1:2014) |
新要求(IEC60598-1:2014+A1:2017) |
Test E: For clip-mounted luminaires: A pull is applied to the cable without jerk for 1 min in the most unfavourable direction in normal use. During the test, the clip is mounted on standard test "shelves" made of ordinary window glass, one with a nominal thickness of 10 mm and one with the maximum thickness onto which the clip can be mounted. For this test, the thickness of the test shelf is increased by multiples of 10 mm. The clip shall not start moving on the glass at a pull of 20 N. |
est E: For clip-mounted luminaires: A pull is applied to the cable without jerk for 1 min in the most unfavourable direction in normal use. During the test, the clip is mounted on standard test “shelves” made of ordinary window glass, one with a nominal thickness of 10 mm and one with the maximum thickness onto which the clip can be mounted. For this test, the thickness of the test shelf is increased by multiples of 10 mm. The clip shall not fall off the glass at a pull of 20 N. |
CTL決議補充: Question: Test for clip- mounted luminaires, pulling in some directions, (direction Z, see the figure). It is practically impossible to have a clip which does not start to move on glass, even though the movement could not degrade the quality of the fixing. Is there any movement permitted?
Decision: Standard has to be followed. The most unfavourable direction must be tried and no movement is allowed. |
None |
新標準接受樣品在測試過程中輕微移動,只要鉗夾裝置不從測試玻璃上拉脫即視為符合標準要求。
在線咨詢
免費為貴公司技術人員提供相應的指導、培訓